Showing 5 results for Shafyei
N. Setoudeh, A. Saidi, A. Shafyei and N. J. Welham,
Volume 25, Issue 1 (7-2006)
Abstract
Anatase-to-rutile phase transformation was studied in milled and unmilled samples. Ball milling was carried out in two types of ball mills, planetary and tumbler, with a ball-to-powder ratio of 40:1 over 2-48 hours. First, the unmilled samples
were heated in the furnace at various temperatures for different periods of time. The results revealed that the anatase-to-rutile transformation completed at 980 after 48 hours. The rate of transformation in milled samples was greatly higher than that of unmilled ones. Activation energy in unmilled samples was about 440 kj/mol. The rate of transformation in the planetary ball mill was higher than that in tumbler mill. In the former, transformation almost finished after 16 hours of milling while in the lattar, it did not finish even after 48 hours. XRD results revealed that the transformation proceeds through an intermediate srilankite phase in all milled samples. However, srilankite was not observed in the unmilled samples.
N. Setoudeh, A. Saidi, A. Shafyei and N.j. Welham,
Volume 27, Issue 2 (1-2009)
Abstract
M. Alizadeh, H. Edris, and A. Shafyei,
Volume 27, Issue 2 (1-2009)
Abstract
S. Torkian, A. Shafyei, M.r. Toroghinejad, M. Safari,
Volume 35, Issue 3 (Journal of Advanced Materials-Fall 2016)
Abstract
In this paper the effect of deep cryogenic treatment time on microstructure and tribological behavior of AISI 5120 case hardennig steel is studied. The disk shape samples were carburized at 920 ◦C for 6 hours and air cooled; after austenitizing, the samples were quenched in oil.Then immediately after quenching and sanding, the sample were kept in liquid nitrogen for 1, 24, 30 and 48 h and then tempered at 200 ◦C for 2 hours. The wear test was done by ball on disk method using of WC ball at 80 and 110 N load. For characterization of carbides, the etchant solution of CuCl2 (5 gr)+HCl (100 mL) + ethanol (100 mL) was used. The hardness of samples before and after of tempering was measured by vicers method at 300 N load.. The amount of retained austenite was measured by X Ray Diffraction method. For 1DCT and 24DCT samples it was about 8% and 4%; in the other samples, the retained austenite peal was so decreased that it was not visible. The result showed that the hardness increases by deep cryogenic treatment in all speciments. While wear resistance increases in 1DCT and 24DCT samples, it decreases for 30DCT and 48DCT samples in compare with Conventional heat treatment (CHT) sample in both applied loads, such that , 48DCT sample has the least wear resistance. The cause of increament of hardness is due to reduction in amount of retained austenite as a result of deep cryogenic treatment and decreasing in wear resistance after 24 hour, is due to carbide growth and nonhemogenuse distribution in microstructure and then weakening of matrix. So the 24 hour deep cryogenic treatment was the best optimal for AISI 5120 steel.
B. Khorrami Mokhori, A. Shafyei,
Volume 35, Issue 4 (Journal of Advanced Materials-Winter 2017)
Abstract
In this research titanium nitride (TiN) films were prepared by plasma assisted chemical vapor deposition using TiCl4, H2, N2 and Ar on the AISI H13 tool steel. Coatings were deposited during different substrate temperatures (460°C, 480 ° C and 510 °C). Wear tests were performed in order to study the acting wear mechanisms in the high(400 °C) and low (25 °C) temperatures by ball on disc method. Coating structure and chemical composition were characterized using scanning electron microscopy, microhardness and X-ray diffraction. Wear test result was described in ambient temprature according to wear rate. It was evidenced that the TiN coating deposited at 460 °C has the least weight loss with the highest hardness value. The best wear resistance was related to the coating with the highest hardness (1800 Vickers). Wear mechanisms were observed to change by changing wear temperatures. The result of wear track indicated that low-temprature wear has surface fatigue but high-temperature wear showed adhesive mechanism.