Search published articles


Showing 3 results for Pcl

M. Ebrahimi and A. Ghaderi,
Volume 24, Issue 2 (1-2006)
Abstract

Stator flux oriented vector control of induction motor (IM) drives for speed sensorless control has several advantages. But the application of a pure integrator for the flux estimation is difficult due to the presence of measurement noise and dc offset. To overcome these problems, some have used a programmable cascaded low pass filter (PCLPF). In this paper, it is shown that some problems still exist and some new problems arise from this approach. In order to solve these problems, a novel compensation method is proposed. In this scheme, the dc offset is detected and subtracted from the estimated flux along d and q axes. The simulation results show that it works well in the low speed region as well as in the transient state. The oscillation of the torque and the estimated flux are also reduced notably when the torque reference changes rapidly.
M. Akbari Taemeh, B. Akbari, J. Nourmohammadi,
Volume 37, Issue 3 (12-2018)
Abstract

In gradient scaffolds, changes in porosity, pore size or chemical composition occur gradually. Recently, different  methods have been applied to create gradient in the scaffolds, but they have some disadvantages such as high cost and control. The main purpose of this research was to fabricate porous gradient scaffolds by a novel, functional, simple, and low-cost method. Two homogenous scaffolds (Homog 1 and Homog 2) and two gradient scaffolds (Grad 1 and Grad 2) were fabricated and compared. Polycaprolactone scaffolds with the pore size gradient along the radial direction were fabricated by combining layer-by-layer assembly and porogen leaching techniques. Paraffin micro particles were used as porogen in two size ranges: 250 to 420 µm and 420 to 600 µm. The average pore size of Homog 1 and Homog 2 was 278.48 ± 11.23 µm and 417.79 ± 14.62, which were suitable for bone tissue engineering. The porosity of the samples was: Homog 1: 77.5 ± 1.25 %, Homog 2: 61.3 ± 3.5 %, Grad 1: 74 ± 0.5 % and Grad 2: 79.8 ± 4 %. It should be stated that the required porosity for cell survival and growth was above 70 %. Compressive strength at 80% strain and compressive modulus for Homog 1, Homog 2, Grad 1 and Grad 2 were 0.16 ± 0.16 MPa and 0.25 ± 0.11 MPa, 0.26 ± 0.20 MPa and 0.53 ± 0.34 MPa, 0.19 ± 0.34 MPa and 0.33 ± 0.43 MPa, 0.12 ± 0.28 MPa and 0.16 ± 0.51 MPa, respectively. The results showed that pore size gradient had a negligible effect on the mechanical properties of the scaffolds and using polycaprolactone (PCL) as the only material of scaffold was not appropriate. The structure of gradient scaffolds showed the radial pore size gradient with a good adhesion between layers without any detectable interface; the result of the compression test also confirmed it.

N. Bahremandi Tolou, H. R. Salimi Jazi, M. Kharaziha, N. Lisi, G. Faggio, A. Tamburrano,
Volume 39, Issue 1 (5-2020)
Abstract

In recent years, graphene has been considered in various tissue engineering applications such as nerve guide conduits because of its unique properties such as high electrical and mechanical properties, porous structure for exchange of nutritious and waste materials, biocompatible, capability of drug and growth factor delivery. In the current study, nerve guide conduits based on a 3D graphene were synthesized by induction heating chemical vapor deposition (ICVD). Graphene was synthesized on Ni foam template at 1080 ͦC. Fabricated samples were characterized by Raman analysis and Scanning Electron Microscopy.  Raman analysis showed that the synthesized graphene is in the form of a turbostratic multilayered graphene with little defects. Cyclododecane (CD) as a temporary protective layer was used to remove nickel. After removing nickel, the free-standing 3D-graphene structure was coated with a polymer (PCL) by drop and dip coating methods to obtain the composite conduit. A comparison of the electromechanical results of the 3D-graphene/PCL conduit and PCL conduit indicated that firstly, grapheme increased the electrical conductivity of the composite conduit which will help promote nerve regeneration and axon growth. Secondly, tensile strength and flexibility of the 3D-graphene/PCL conduit was improved compared to the PCL conduit.


Page 1 from 1     

© 2024 CC BY-NC 4.0 | Journal of Advanced Materials in Engineering (Esteghlal)

Designed & Developed by : Yektaweb