Volume 28, Issue 1 (Spring 2024)                   jwss 2024, 28(1): 81-91 | Back to browse issues page


XML Persian Abstract Print


Department of Water Science and Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran. , drmasjedi.2007@yahoo.com
Abstract:   (118 Views)
The use of structures has economic and safety advantages compared to other energy-consuming structures. In this research, to investigate the effect of the length of the sill of the flip bucket spillway on the scour downstream, experiments were conducted in a rectangular laboratory flume made of Plexiglas. The scouring downstream of the flip bucket spillway was investigated using a flip bucket spillway with four relative sill lengths and four threshold angles at four current intensities in the channel in this research. The results of this research showed that by the increase in the length of the sill in the flip bucket spillway, the energy consumption in the spillway increased and the scour depth downstream decreased. Also, increasing the relative length of the sill by 70% at the sill angle of 45 degrees, the scouring depth is reduced by about 88%. Also, a relationship was presented to determine the maximum depth of relative scour, and the correlation coefficient of the results obtained from this equation with the laboratory results is about 0.92.
Full-Text [PDF 476 kb]   (103 Downloads)    
Type of Study: Research | Subject: Ggeneral
Received: 2023/08/30 | Accepted: 2023/11/20 | Published: 2024/05/30

Rights and permissions