Search published articles


Showing 1 results for P. Shojaei

P. Shojaei, D. Farsadizadeh , A. Hoseinzadeh Dalir,
Volume 15, Issue 57 (fall 2011)
Abstract

Submerged vanes are low aspect ratio flow-training structures mounted vertically on the river bed at an angle to the prevailing flow. The aim of application of vane is to generate a secondary circulation in the main flow, designed to modify the near-bed flow pattern and thus redistribute flow and sediment transport within the channel cross section. Collar is a flat sheet with low thickness fixed vertically on the pier at stream bed level or near it. Installation of a collar leads to protect the river bed against the direct impact of downflow produced at the upstream face of the pier and therefore reduces the scour depth. This research is a laboratory study that examines the effectiveness of submerged vanes and combination of submerged vanes and collar as a pier scour protection device. Experiments were conducted in an 8 m long and 0.8 m wide flume and a cylindrical pier used was 6 cm in diameter. Clear-water scour tests with u*/u*c = 0.9 were performed with a collar 3 times wider than the pier diameter at the stream bed level and submerged vanes 1.5 times longer than the pier diameter at the stream bed level (H=0). Different arrays of vanes with different angles to main flow direction were employed. The highest reduction in the depth of scour hole with four vanes and a collar showed 61% reduction in scour depth.

Page 1 from 1     

© 2024 CC BY-NC 4.0 | JWSS - Isfahan University of Technology

Designed & Developed by : Yektaweb