Search published articles


Showing 2 results for Eurosem Model

A. Jalalian, M. Amirpour Robat, B. Ghorbani, S.h. Ayoubi,
Volume 11, Issue 42 (1-2008)
Abstract

  Soil erosion is one of the most threatening issues for crop production and environmental qualities, especially for soil and water resources. Appropriate knowledge about total soil loss and runoff is valuable in order to perform soil and water conservation practices in watersheds. EUROSEM, "a single event, dynamic and distributed model," was developed to simulate soil loss, sediment transportation and deposition by rill and interrill processes. This study was conducted to evaluate EUROSEM model in order to simulate soil loss and runoff in Sulijan sub-basin, which covered 20 ha, from Charmah-Bakhtari province. The sub-basin was divided in to 19 homogeneous elements using topographic, land use, plant cover, slope and channel properties throughout it. Soil, plant cover, land surface and climate characteristics were measured and evaluated by field observations and laboratory measurements. Actual soil loss and runoff for studied events were determined by direct measurement in the field. After sensitivity analysis, calibration and validation steps were carried out to simulate runoff and soil loss. The results of sensitivity analysis showed that the EUROSEM model for predicting runoff was more sensitive to hydraulic conductivity, capillary drive and initial soil moisture. On the other hand the model for predicting soil loss was more sensitive to Manning's coefficient and soil cohesion. The results showed that the EUROSEM model was able to simulate well the total runoff, peak of runoff discharge, total soil loss and time for the peak of soil loss discharge. But that could not simulate well the peak of soil loss discharge and time for the peak of runoff. Although it seems that EUROSEM is able to predict soil loss and runoff partially well in individual events, it is necessary to evaluate the efficiency of the models for different basins with varieties of soil, plant cover and climatic properties.


M. Hamidpour, A. Jalalian, M. Afyuni, B. Ghorbani,
Volume 16, Issue 62 (3-2013)
Abstract

Models are helpful tools to predict runoff, sediment and soil erosion in watershed conservation practices. The objectives of this research were to investigate sensitivity analysis, calibration and validation of EUROSEM model in estimation of runoff in Tangh-e-Ravagh sub-basin of Karoun watershed. The model was tested in a one hectare experimental test site. The area was divided into nine elements according to EUROSEM user's manual. A triangular weir was installed at the outlet of the area to collect runoff in specified time periods for six rainfall events. Sensitivity analysis of the model was performed by a ±10% change in the dynamic parameters of the model and examining the outputs for a rainstorm. Sensitivity analysis showed that total runoff was sensitive to saturated hydraulic conductivity and insensitive to soil cohesion. Sensitivity analysis indicated that the model sensitivity depends on evaluation conditions and it is site-specific in nature. Calibration and validation of the model was performed on input parameters. Calibration of hydrographs was performed by decreasing saturated hydraulic conductivity and capillary drive and increasing initial soil moisture. Validation results showed that EUROSEM model simulated well the total runoff and peak of runoff discharge, but it could not simulate well the time of runoff, time to peak discharge

Page 1 from 1     

© 2024 CC BY-NC 4.0 | JWSS - Isfahan University of Technology

Designed & Developed by : Yektaweb