Search published articles


Showing 1 results for Flow Rate Coefficient of Variation

F. Gavazi, E. Maroufpoor,
Volume 21, Issue 1 (6-2017)
Abstract

The main purpose of this study is investigation of hydraulic properties in drip irrigation tape. In this study, 10 types of drip irrigation tape were tested, and the effect of 4 temperatures of water, 13, 23, 33 and 43 °C, was investigated according to the standard ISO 9261 and ISO IRISI. Initially all experiments were performed in standard temperature (23°C) in order to obtain qualitative evaluation indexes of tapes. The results obtained were as follows: According to the Cv, 8 models of tapes were ranked as good and 2 models as medium. According to the difference between the actual and nominal flow rates, 3 models were ranked as good, 3 models as medium, 3 models were acceptable and 2 models were unacceptable. According to the EU, 9 models were ranked as excellent and T3 was ranked as good. According to the UC, UC of all models was more than 70% and their flow rate variation follows normal distribution. According to qvar, flow rate changes in 3 models were acceptable, 2 models were ranked as good and 5 models were unacceptable.
 



Page 1 from 1     

© 2024 CC BY-NC 4.0 | JWSS - Isfahan University of Technology

Designed & Developed by : Yektaweb